Spatial Characteristics Inventory: field procedures
How to observe and record each of the 56 items. The field sheets and the workbook give the rule for what counts; this page explains how to check it.
Jump to Before you start, Building items, or room items for Indoor Environmental Quality, Spatial Functionality and Environmental Character.
Before you start
- Pick the day
- Visit on a normal instructional day with students present.
- Choose your rooms
- Sample 8 primary learning spaces, or all of them if there are fewer. Cover every grade band, wing or addition era, façade orientation and floor, including the oldest wing and any portables. Choose the rooms yourself; don’t let the building pick them for you. Every room item is scored against this same list.
- Record conditions
- Before the walk, record whether it’s a normal instructional day, whether students are present, the HVAC mode, the sky and the outdoor temperature. In each room, record the time and the sky.
- What to bring
- A tape measure (CON_1, ACC_4), a camera or phone, and the field sheets or workbook.
- Cannot Determine
- Use it only after you have both looked for yourself and asked facilities staff. Write who you asked in Notes. It records a gap in what the school can document, so it isn’t a neutral answer.
- Reverse-scored items
- For most items, Yes is the condition you want. TC_4 (supplemental heating and cooling devices) and VI_1 (uniform surfaces) are the exceptions: there, Yes flags a problem.
- Rooms that don’t apply
- Where an item can’t apply to a room, such as TC_3 in a room with no exterior windows, choose that option. The room is left out of the count for that item.
- Photos
- Name each photo by item and room, for example VI_3_Rm112.jpg. Score ACC_4, VI_1 and VI_3 from the photo.
Building items
Answer once for the whole school. Most of the first block comes from a conversation with facilities staff, before or after the walk.
Facilities conversation
Ask before or after the walk.
IAQ_2 Air Filtration Quality
Are the primary HVAC system's air filters rated MERV 13 or higher?
Ask facilities staff.
- Ask facilities staff to open one heating and cooling unit in each wing you sampled.
- Find the filter's MERV rating printed on the edge of its frame and photograph it. A higher number means cleaner air.
- If you can't see the filter, check filter purchase orders or the maintenance log.
- Some filters use other scales: FPR 10 is about MERV 13, and MPR 1500–1900 is about MERV 12–13.
- Record the lowest rating you find, not the highest.
- If the building has no ducted system with filters (only windows, or units with no filter slot), mark "Do not have mechanical ventilation."
TC_2 Mechanical Cooling Availability
Was mechanical cooling available in primary learning spaces all or most of the time last school year?
Ask facilities staff.
- Find out what cools each sampled room: a wall or ceiling unit, a rooftop unit, a window AC unit, or nothing.
- Ask facilities staff about cooling repair requests from last school year and any wing or season without cooling.
- Choose "All of the time" if every room is cooled with no outages, and "Most" if there were only short or one-off outages.
- Choose "Some" if a wing or season goes without cooling, such as none at the August start.
- Choose "Rarely" if there are only window units or portable cooling, and "None" if there is no mechanical cooling.
MC_1 Daily Cleaning Practices
Is there a written daily cleaning schedule with signed logs for the past two weeks, and nothing seen midday that contradicts them?
Ask facilities staff.
- Ask the custodial supervisor for the written cleaning schedule and the daily checklist.
- Ask for signed daily cleaning logs for the sampled rooms over the past two weeks.
- Ask how much floor area each custodian covers. About 28,000–31,000 sq ft per person is typical for K–12 schools.
- Around midday, look for overflowing trash, dust on sills and ledges, and dirty floors. If what you see contradicts the logs, trust what you see.
- Mark Yes only if there is a written daily schedule, signed logs, and nothing you saw contradicts them.
MC_2 HVAC Maintenance Schedule
Do dated records show HVAC filters were replaced AND the systems serviced within the past six months?
Ask facilities staff.
- Ask facilities staff for the repair and maintenance records of the specific units that serve the sampled rooms, not a district-wide statement.
- Many crews write the change date on the filter frame. If you see one, photograph it.
- Pull out one filter. Heavy dust, a collapsed filter, or gaps around the frame suggest the records aren't accurate.
- Mark Yes only if dated records show both a filter change and a system service in the last six months.
- If there is no dated record, mark Not sure rather than Yes.
MC_3 Humidity Control
Are all sampled wings served by systems that actively control humidity (dehumidification or AC sized to remove moisture)?
Ask facilities staff.
- Ask facilities staff whether the sampled rooms have equipment that removes moisture from the air, such as a dehumidifier or an AC system sized for it.
- Ask whether it runs in summer and when the building is empty.
- If the building's control system tracks humidity, check the readings. Between 30% and 60% is the usual target.
- As you walk, look and smell for moisture: a musty odor, ring-shaped stains on ceiling tiles, condensation on windows or air vents, and peeling paint at outside corners and sills.
- Record the room number and take a photo, describing only what you see.
- Mark Yes only if every sampled wing is served.
CON_5 Access to Teacher Spaces
Do teachers have a dedicated planning space, with a work surface and seat for each assigned teacher, available during planning periods?
Ask facilities staff.
- Find the teachers' planning space. It may be a dedicated workroom or planning areas inside classroom clusters.
- It needs a work surface and a seat for each teacher assigned there, not just a copier and mailboxes.
- Ask two or three teachers where they actually plan during their planning period.
- If every teacher says "in my classroom," mark No, whatever the floor plan shows.
- Mark Yes if a dedicated space exists and is available during planning periods.
TECH_3 Tech Support for Diverse Learning Needs
Is there a written list of assistive technology for students with disabilities, AND did you see at least two items on site?
Ask facilities staff.
- Ask the special education lead or building coordinator for the list of assistive technology and how students request it.
- See at least two items in the building yourself. Examples include a hearing-assist system (FM/DM) on its charger, a captioned display, screen-reader or text-to-speech software, or a speech device (AAC) for students who don't speak.
- Mark Yes only if there is a written list and you saw two items on site.
- If the answer is "the district provides it on request" and nothing is in the building, mark No.
ACC_6 Lactation Room
Is there an available lactation room (not a restroom) with a sink, cold storage, mirror and chair?
Ask facilities staff and observe.
- Ask the front office to show you the room. Don't accept "we have one somewhere."
- Check for all four items: a sink (in the room or right next to it), a refrigerator or other cold storage, a mirror and a chair.
- Also check that the room locks from inside, has an electrical outlet, and isn't a restroom.
- Mark Yes only if all four items are there and the room is available, meaning it isn't locked with no key or full of storage.
- Note if the room doubles as the nurse's office, a storage room or a meeting room.
ACC_7 Student Retreat Spaces
Is there a space students can choose to use for privacy and self-regulation (not a discipline/time-out room) that is usable today?
Ask facilities staff and observe.
- Look for a place where students can go to calm down or have privacy, such as a calming corner in a classroom, a sensory room, a counselor's space or a library nook.
- It counts if a student can use it without being sent there for discipline.
- It must be usable right now, not full of boxes.
- It must give real privacy from sight or sound.
- A time-out or de-escalation room used for discipline is a different kind of space. If that's what you find, say so instead of counting it.
- In the answer field, describe where it is, its rough size, whether it's in a classroom or shared, and how it's supervised.
ACC_8 Educator Retreat Spaces
Is there a space where one teacher can be alone and unseen for 10 minutes during the school day?
Ask facilities staff and observe.
- Find a space where teachers can go for privacy, and note how they get into it.
- It counts if one teacher can be alone and unseen there for 10 minutes during the school day.
- A staff lounge that is also the copy, mail and meeting room does not count, and neither does a shared workroom.
- The nurse's cot is not a retreat space.
- In the answer field, describe where it is, its size, whether it locks, and whether teachers say they use it.
On the walk
Observe and test; bring a tape for CON_1.
WAT_1 Bottle Filling Stations
Does every sampled room have a clean, working bottle filling station on its floor or wing that students can reach between classes?
- Find every bottle filling station in the building and mark each one on the floor plan.
- The target is one working station per floor in each wing, within about a 2-minute walk (about 250 ft) of the sampled rooms.
- Test at least three stations. Check that water comes out at full flow, the filter light is green, and the basin is clean and undamaged.
- Mark Yes only if every sampled room has a station on its floor or wing that students can reach between classes, and every station you tested worked.
- Mark No if any station is dry, shows a red light, or is bagged off.
WAT_2 Water-Efficient Fixtures
Do most toilets and urinals checked meet water-efficiency standards (toilets ≤1.28 gpf; urinals ≤0.5 gpf or waterless)?
- Check two restrooms on each floor, one for students and one for staff.
- Find the gallons-per-flush (gpf) stamp on each toilet and urinal. It is printed on the porcelain near the seat hinge, on the flush valve, or under the tank lid.
- Photograph the stamp. Don't guess from how the fixture looks.
- A toilet meets the standard at 1.28 gpf or less. A urinal meets it at 0.5 gpf or less, or if it is waterless.
- Mark Yes if most of the fixtures you checked meet the standard, and record how many did and didn't.
WAT_3 Educator Plumbing Infrastructure
Do ALL tested teacher/staff restroom fixtures operate with no leaks, standing water, water stains, corrosion, loose parts or sewer odor?
- Check teacher and staff restrooms only, the same number you check for WAT_4.
- Flush each toilet once, and run each faucet for 10 seconds while watching the drain clear.
- Look for dripping or running water, standing water, water stains on ceiling tiles or the base of walls, corroded pipes, loose fixtures and sewer smells.
- A fixture passes only if you find none of these.
- Record how many fixtures passed out of how many you tested, with the room number and a photo of any failure.
WAT_4 Student Plumbing Infrastructure
Do ALL tested student restroom fixtures operate with no leaks, standing water, water stains, corrosion, loose parts or sewer odor?
- Check student restrooms only: at least one per floor in each wing, plus one in the oldest part of the building.
- Flush each toilet once, and run each faucet for 10 seconds while watching the drain clear.
- Look for dripping or running water, standing water, water stains on ceiling tiles or the base of walls, corroded pipes, loose fixtures and sewer smells.
- A fixture passes only if you find none of these.
- Record how many fixtures passed out of how many you tested, with the room number and a photo of any failure.
CON_1 Wide Corridors for Circulation
Is the average passable corridor width more than 8 feet (excluding lockers, fountains, cases and columns)?
Bring a tape measure.
- Measure three hallway sections: the main hallway, a typical classroom wing, and the narrowest point in the building.
- You can use the tape, or count the ceiling tiles across the hallway and multiply by the tile size. Check the tile size once with the tape first (usually 2×2 or 2×4 ft).
- If there is no ceiling grid, count floor tiles (usually 12 in, or 9 in in buildings from before 1980) or pace it off after measuring your stride against the tape.
- Tape one section to confirm your tile count before relying on it.
- Subtract anything that narrows the walking path, such as lockers (12–15 in deep, or 18 in with sloped tops), drinking fountains, display cases and columns.
- Record the average width of the three sections, and record the narrowest one separately.
ACC_3 Lever Handles and Low-resistance Doors
Do all seven doors tested have lever or push/pull hardware and open with 5 lb of force or less?
- Test seven doors: the main entry, two hallway doors, three classroom doors and one restroom.
- Check the handle. A lever, push/pull bar or push bar passes, and any round knob fails.
- Hook a luggage scale on the handle and pull straight out. Interior doors that aren't fire doors should open with 5 lb of force or less (the ADA limit).
- Without a scale, a door passes if one hooked finger opens it smoothly, and fails if it takes a shoulder or two hands.
- Open the door fully and let go. It should take at least 5 seconds to close.
- Mark No if you find any knob or any door that fails the force test.
ACC_5 Visual Floor or Wall Cues for Spatial Transitions
Do at least three of five key transitions have an intentional sensory cue (change in flooring, ceiling, color, lighting or texture)?
- Pick five transitions on your walk: classroom to hallway, hallway to commons, hallway to gym or cafeteria, entry to lobby, and one wing to another.
- At each, look for intentional cues that signal you're entering a new space.
- Cues include a change in flooring material or color, a change in ceiling height or material, a color band at the doorway, a change in lighting, a framed opening or lowered ceiling, or a change in wall texture.
- Wear, a mismatched repair patch, or the seam where an addition meets the old building does not count.
- Mark Yes if at least three of the five transitions have at least one cue.
LEG_1 Color-coded or Themed Zones
Are learning zones distinguished by a consistent wayfinding system (color, graphics or numbering) repeated in at least three places?
- Walk the whole building once with a floor plan in hand.
- Look for a wayfinding system, not just a single accent: a repeated, intentional color, graphic style or numbering for each wing, neighborhood or grade.
- The system should show up on doors, walls or floors in at least three places.
- Ask a student or front office staff member, "How would a visitor find the 6th grade wing?" If the answer depends on someone walking them there, mark No.
- Mark Yes only if the system is consistent and repeated. One accent wall is not a system.
LEG_2 Visual Landmarks
Is there at least one visual landmark at a decision point in each wing or on each floor?
- Look for distinct, memorable landmarks, such as a mural, mascot graphic, trophy case, open stair, or a distinctive structural feature or material.
- Mark each one on the floor plan.
- Check where they sit. Landmarks should be at decision points, such as hallway intersections, stair landings and wing entrances, not only at the main entry.
- Mark Yes if at least one landmark sits at a decision point in each wing or on each floor.
LEG_3 Defined Spatial Layout Pattern
Does the building have a cohesive layout pattern (loop, double-loaded corridor, spoke/finger, courtyard, cluster or axis)?
- Use the floor plan. The fire evacuation plan posted in the hallway works.
- Trace the main hallways and name the pattern: a loop, a straight hallway with rooms on both sides, a spoke or finger plan, a courtyard, clusters or neighborhoods, or a central axis.
- Walk it. Starting at the main entry, check whether you can get back to where you started without backtracking, and count how many decision points you passed.
- If additions break the original pattern, answer Yes and describe it as a hybrid, naming both patterns and where they meet.
- Describe the layout in the answer field.
LEG_4 Distinction between Public and Private Zones
Is there a physical boundary between public and classroom zones that lets public areas be used after hours without opening classrooms?
- Find where the public zone (entry, main office, gym, cafeteria, auditorium and community rooms) meets the classroom zone.
- Look for a physical marker at that boundary, such as a lockable gate across the hallway, a vestibule, a badge-controlled door, or a change in ceiling, flooring, signage or lighting.
- Mark Yes if there is a physical boundary and the public zone can be used after hours without opening the classroom zone.
- Being close together isn't enough. "The office is near the front" is a No.
Room items
Answer for each of your sampled rooms, finishing every item in one room before you move to the next.
Indoor environmental quality
Indoor Air Quality
IAQ_1 Operable Windows / Natural Ventilation
Does the room have at least one window that opens?
- Look for windows that are meant to open, such as those with a crank, latch or handle.
- Try to open one. If it opens, the room counts.
- A window that is painted or screwed shut, is missing its crank, or is stuck does not count.
- A locked window counts only if staff confirm the key is kept at the school.
- Note anything blocking the window, like furniture or a wall AC unit, and whether district policy keeps windows closed.
IAQ_3 Supplemental Air Cleaning
Is there a working portable air purifier labeled "True HEPA" or "H13"?
- Look for portable air purifiers on floors, counters or carts.
- A purifier counts only if it is plugged in, running during class, and labeled "True HEPA" or "H13."
- Units labeled "HEPA-type," ionizers and UV-only cleaners do not count.
- Units switched off because of noise or stored in a closet do not count.
- Note whether the filter-change light is on, and ask staff how often the units run.
Acoustics
ACOU_1 Sound Absorption
Is at least 80% of the ceiling sound-absorbing, with no ring or echo when you clap once?
- Count all the ceiling tiles in the room.
- Tap the tiles. A dull thud means the tile absorbs sound; a sharp knock means it reflects sound, as drywall, hard tile, plaster and exposed deck do.
- Count the reflective tiles. Any acoustic panels on the walls add to the sound-absorbing side.
- Stand in the middle of the room and clap once, sharply. If you hear a ring or echo, the room does not count, whatever the tile count.
- The room counts if at least 80% of the ceiling absorbs sound and the clap dies away quickly.
- Lift one tile and photograph the maker's stamp on the back. Look up its sound rating (NRC; 0.75 or higher is the target) once for the building.
ACOU_2 Voice Amplification Systems
Is there a working voice amplification system (teacher microphone plus classroom speakers)?
- Look for a microphone the teacher wears, its charger, and ceiling speakers connected to a classroom amplifier.
- Turn the system on and ask the teacher whether they used it this week.
- The room counts if the system works and is in use.
- A microphone sitting in a drawer with a dead battery does not count.
- Building PA or intercom speakers alone do not count.
Thermal Comfort
TC_1 Local Thermal Control
Can the teacher adjust the room temperature from a control in the room?
- Find the thermostat or heating and cooling control in the room.
- Check whether the teacher can actually change the temperature with it.
- It does not count if it has a locked cover, only displays the temperature, or is overridden by a central building system.
- Ask facilities staff whether room adjustments are turned on, and by how much the temperature can change (for example, ±2 °F).
- If one thermostat serves several rooms, count only the room it is in.
TC_3 Window Coverings
Do the exterior windows have shades or blinds that raise, lower and stay in place?
- Find the shades or blinds on windows that face outside.
- Lower and raise one in each room. It counts if it moves and stays where you put it.
- Missing slats, broken cords, taped-up paper or cardboard, and blinds blocked by cabinets do not count. Photograph these.
- Leave rooms with no exterior windows out of the count, and record how many you left out.
TC_4 Supplemental Thermal Control
Does the room have supplemental cooling or heating devices (e.g., personal heaters, fans, window AC)?
- Look for personal fans, space heaters and window AC units in the room.
- Ask the teacher about devices stored on top of cabinets between seasons, and count those too.
- The room counts if it has at least one device. Photograph them.
- These devices signal that the room isn't comfortable, so read them as a problem, not a feature.
- If many rooms have them, compare your results with TC_1 and TC_2.
Lighting Conditions
LIGHT_1 Daylight Access
With shades open and lights off, can you read 12-point text from the seat farthest from the window?
- Check this between 9 a.m. and 2 p.m., and record the sky condition in the Conditions box at the start of the form.
- Open the shades and turn off the lights.
- Sit at the student seat farthest from the window. The room counts if you can read regular 12-point text.
- For a more exact check, use a phone light-meter app at desk height (about 30 in). A reading of 150 lux or more is usable daylight, and 300 lux or more is full task light.
- Note where the daylight comes from (window, high window or skylight) and anything permanently blocking it, such as window film, stacked storage or a portable building next door.
LIGHT_2 Adjustable Lighting Systems
Can the lighting be adjusted beyond on/off (dimmer, multi-level switch, color tuning, or daylight/scheduled dimming)?
- Try the light switches in the room.
- The room counts if it has a dimmer, a switch with several brightness levels, or a keypad that changes the light color.
- Lights that adjust on their own also count, such as lights that dim when daylight is bright or follow a programmed schedule.
- A single on/off switch, or a motion sensor that only turns lights on and off, does not count.
LIGHT_3 Varied Electric Lighting
Are two or more different types of light fixtures present and working?
- Look at the kinds of light fixtures in the room, such as recessed ceiling panels, hanging lights, wall lights, hidden cove lighting, and desk or floor lamps.
- The room counts if two or more different kinds are present and turned on.
- A grid of identical ceiling panels does not count.
- Ceiling panels plus a floor lamp the teacher brought in does count, but note that the teacher added it.
- Photograph the ceiling straight up from the center of the room.
Spatial functionality
Connectivity
CON_2 Glass Walls or Large Interior Windows between Learning Spaces
Is there see-through interior glass larger than the door's vision panel (glass wall, sidelight or interior window)?
- Look for interior glass you can see through into other spaces, such as glass panels beside doors, interior windows or glass walls.
- The glass must be wider than the small window in a classroom door. That narrow door window (about 5 × 20 in) does not count on its own.
- The glass must be see-through today. Glass covered with posters or a blind does not count.
- Record how many rooms have covered glass, since it is a common and important finding.
CON_3 Adjacency of Small Group Learning Spaces to Classrooms
Is there a designated small-group space (2–8 students) that shares a wall, door or clear sightline with the room and is usable now?
- Look for a small room or alcove sized for 2–8 students that shares a wall, a door or a clear line of sight with the classroom.
- It must be set aside for small-group work and usable right now, not full of boxes.
- A shared conference room down the hall or a storage room does not count.
- An open hallway nook with no separation for sound or sight does not count.
CON_4 Adjacency of Learning Zones to Classrooms
Is there a furnished open learning area (commons, breakout, widened hallway) next to or visible from the room?
- Look for open space just outside the classroom, such as a shared learning area, a commons or a widened hallway, that is next to or visible from the room.
- It counts if it has furniture set up for work and is in use.
- A bare hallway, or a space used for overflow storage, does not count.
- Photograph one space that counts and one that doesn't.
CON_6 Physical Connection to Outdoors
Is there a door from the room (directly or via a small vestibule) that can be used to go outside during the school day?
- Look for a door that leads straight outside, or outside through a small entry area.
- Check that the door can actually be used: it opens from inside (unlocked or with a badge), has no alarm, and is allowed during the school day.
- Confirm the security policy with facilities staff.
- The room counts only if the door is usable.
- Separately, record how many rooms have an outside door that security policy keeps locked, since that matters for planning.
Technology
TECH_1 Charging Stations or Outlet Clusters in Common Areas
Are there enough reachable outlets (or charging-cart slots) for every student device to charge at the same time?
- Count the outlets students can reach, leaving out any blocked by cabinets or furniture.
- Include a charging cart if it is kept and used in the room.
- Compare the count with the number of students the room holds. The room counts if every student device can charge at the same time.
- Note any power strips plugged into each other, or extension cords running across the floor or into the hallway. These show there are too few outlets and are also a safety-code issue.
TECH_2 Smart Boards or Interactive Whiteboards
Is there a working interactive board (turns on, touch lands accurately, pen present and charged)?
- Turn on the interactive board and touch it.
- It counts if it turns on, your touch lands where you point, and the pen is there and charged.
- It does not count if it is unplugged, only used as a projection screen, mounted too high for the teacher to reach, or covered by a whiteboard or paper.
- It also does not count if your touch lands far from where you point.
- Note whether it is a touchscreen panel or a projector with a board, since each tends to fail in different ways.
TECH_4 Sensor-based Systems (Lighting, HVAC, Occupancy)
Do motion sensors turn the lights on within ~3 seconds and keep them on while you sit still for 3 minutes?
Ask facilities staff.
- Look for motion sensors that control the lights.
- Walk into the room and count the seconds until the lights come on. More than about 3 seconds is a fail.
- Sit still for 3 minutes. If the lights turn off, the sensor isn't set up for classroom use.
- Sensors that are taped over, covered with paper, or bypassed at the switch do not count.
- If there are daylight or CO2 (air quality) sensors, ask facilities staff when they were last adjusted.
- The room counts only if sensors exist and pass both tests. If no room has sensors, mark None.
Accessibility
ACC_1 Multi-height Work Surfaces or Seating
Can students work at two or more surface heights, with seating that fits each?
- Count the different work-surface heights students use. Typical heights are low or floor level (18–22 in), seated (29–30 in), counter (36 in) and standing (40–42 in).
- The room counts if students can use two or more heights, with seating that fits each one.
- The teacher's desk does not count.
- A standing counter along the wall counts only if students actually work there.
ACC_2 Signage
Does the room's permanent sign include an icon, a second language and Braille?
- Check at least 10 permanent room signs at restrooms and classrooms across your sample.
- On each sign, look for raised letters, Braille below the text, an icon or picture, and a second language.
- Check that the sign is on the door-handle side and 48–60 in above the floor.
- A sign counts if it has an icon, a second language and Braille.
- Paper signs taped to a door do not count.
- Record how many signs meet the standard out of how many you checked.
ACC_4 Clear Floor Space for Wheelchair Turning
With furniture as normally arranged, is there a clear 60-inch turning circle plus a 36-inch path from the door to a work surface?
Bring a tape measure.
- Look for an open circle 60 in across, the space a wheelchair needs to turn, in the usable part of the room.
- It can't be under a table, in the door's swing, or out in the hallway.
- To size it, use five 12 in floor tiles, 2.5 ceiling tiles on a 2 ft grid, or a door's width (36 in) plus 2 ft. Check the tile size once with the tape.
- Also check for a clear path at least 36 in wide from the door to at least one work surface.
- Judge the room with the furniture where it normally sits. Don't move anything to make it fit.
- Photograph the spot with the tape or a person in it for scale.
ACC_9 Handedness
Does the furniture work for both left- and right-handed students?
- Count the chairs with a built-in writing arm, and how many have the arm on the left side.
- The room counts if its furniture works for either hand, such as rectangular tables or standard desks with a centered top.
- It also counts if left-arm chairs make up at least 10% of the writing-arm chairs.
- If there are shared tools like scissors or instruments, check whether left-handed versions are available.
- Mark Yes if most sampled rooms meet the standard.
ACC_10 Size Appropriateness
Do chairs and desks fit the students using them (feet flat, knees about 90°, forearms resting on desk)?
- Measure the seat height and desk height with the tape.
- Typical seat heights are 10–12 in for PreK–K, 14–16 in for grades 1–4, 16–18 in for grades 5–8, and 18 in for grades 9–12. There should be 8–12 in between the seat and the underside of the desk.
- Watch five seated students. Their feet should rest flat on the floor, knees at about a right angle, and forearms on the desk without shrugging.
- Feet dangling or knees jammed under the desk mean the furniture doesn't fit.
- Note if one chair size is used by several grade levels in a shared room. It's a common problem and worth reporting.
- Mark Yes if most sampled rooms meet the standard.
Furniture & Function
FF_1 Movable Panels
Is there a working movable wall or partition that lets the room be reconfigured?
- Look for folding or sliding walls, movable partitions, or overhead doors between spaces.
- Open and close one. It should run smoothly along its track, latch, and close tightly.
- A partition that is screwed shut, blocked by cabinets, or has damaged seals does not count.
- Ask the teacher how many times a month it is actually moved. The room counts only if it works and is used.
- If you can see the sound rating label (STC) on the panel edge, photograph it.
FF_2 Variety of Flexible Furnishings
Are there two or more types of student seating, AND can one student move a chair and table alone?
- Count the kinds of seating students can use, such as standard chairs, stools, soft or lounge seats, floor cushions, wobble seats, benches and standing spots.
- Check whether one student could slide or lift a chair and move a table alone.
- The room counts if it has two or more kinds of seating and students can move the furniture.
- Photograph the room from a back corner so the whole layout shows.
FF_3 Display Space
Is there about 16 ft of pin-up surface plus student-reachable marker surface, 30–72 in above the floor, where students work?
- Measure the total length of pin-up, magnetic and marker surfaces between 30 and 72 in above the floor. Skip the projection area on the front wall.
- Counting 4 ft panels is faster than using the tape.
- The target is about 16 ft of pin-up surface, plus a marker surface students can reach without a ladder, placed where they work rather than behind the door.
- Ask the teacher whether there is enough display space and whether it's in the right place.
- If work is taped to painted walls, windows or cabinet fronts, mark No.
- Mark Yes if most sampled rooms meet the standard.
FF_4 Storage
Is storage sufficient, with no teaching materials on floors or sills, and does the teacher confirm it works?
- Look at how much cabinet space the room has, whether the doors and drawers close, and whether the teacher has lockable storage.
- Look for signs that storage falls short: bins stacked on the floor, materials on window sills, boxes on top of cabinets, or shelving brought from home.
- Materials on sills also block daylight, so compare with LIGHT_1.
- Ask the teacher whether the amount, type and location of storage work for them.
- Mark Yes if no teaching materials are stored on floors or sills and the teacher confirms storage works.
- Mark No if any one of those signs shows up in most sampled rooms.
Environmental character
Biophilia
BIO_1 Views to Natural Elements
From a seated student's eye level (~44 in) mid-room, can you see natural elements (trees, plantings, water or open sky)?
- Sit at a student seat in the middle of the room, or crouch to seated eye level (about 44 in), and look outside.
- The room counts only if you can see nature from that seat, not just from standing at the window.
- Trees, grass, plantings, courtyard greenery, water and open sky count.
- A parking lot, a roof, a nearby wall or a paved courtyard does not count.
- Record sky-only views separately from views with plants or trees. Both count, but they are not the same.
- Take the photo from the seat, not from the window.
BIO_2 Indoor Vegetation
Are live plants present?
- Look for live plants, green walls, planted terrariums or classroom gardens.
- Check the leaves. Fake plants are common and easy to mistake from a distance, so they don't count. Note them separately.
- The room counts if it has any live plants. Even one pot on the windowsill counts.
- Note whether it is a single plant or a larger installation.
BIO_3 Presence of Water Features
Is a working, cared-for water feature (aquarium, fountain, water table) in or visible from the room?
- Look for an aquarium, indoor fountain, water table or other water feature that you can see or hear from inside the room.
- It must be running and cared for. A dry fountain, an empty or cloudy tank, or an unplugged feature does not count.
- Drinking fountains and bottle fillers do not count.
- Mark Yes if a working water feature is in, or visible from, most of the sampled rooms.
BIO_4 Biophilic Ceiling
Does at least a quarter of the ceiling (or an intentional feature) use natural materials or natural patterns?
- Look up at the ceiling and check for natural materials, such as real wood, stone, cork, bamboo, wool or felt.
- Also check for natural patterns, such as leaves, waves, wood grain, branching shapes or organic curves.
- The material or pattern must cover at least a quarter of the ceiling, or be an intentional feature, like a wood panel over the reading area. A thin trim strip does not count.
- Record which one you found. A tile printed to look like wood is a pattern, not a natural material.
- Photograph the ceiling straight up.
- Mark Yes if most sampled rooms meet the standard.
BIO_5 Biophilic Flooring
Does at least a quarter of the floor (or a defined area) use natural materials or natural patterns?
- Look at the floor and check for natural materials, such as wood, stone, cork, bamboo or wool.
- Also check for natural patterns, such as organic shapes, waves, grain or branching designs in carpet or vinyl flooring.
- The material or pattern must cover at least a quarter of the floor, or mark off a defined area, like a wood-look reading corner.
- The speckled vinyl tile common in schools is not a natural pattern, so don't count it.
- Record which one you found. Wood-look vinyl and laminate are patterns, not natural materials.
- Photograph the floor straight down.
- Mark Yes if most sampled rooms meet the standard.
BIO_6 Biophilic Walls
Does at least a quarter of one wall (or a feature wall) use natural materials or natural patterns?
- Look at the walls and check for natural materials, such as wood, stone, cork, brick, bamboo, or felt or wool panels.
- Also check for natural patterns, such as leaves, waves, grain, branching shapes or organic curves, in wallcovering, tackboard or a mural of nature.
- The material or pattern must cover at least a quarter of one wall, or be an intentional feature wall.
- Exposed concrete block or brick counts as a natural material. Note it, because it also affects sound in the room (see ACOU_1).
- Record whether you found a material or a pattern.
- Photograph each qualifying wall straight on.
- Mark Yes if most sampled rooms meet the standard.
Visual Interest
VI_1 Neutral Materials or Textures
Are the wall, floor and ceiling surfaces monochromatic or uniform in material and texture?
- This item is scored in reverse: a high count means less visual variety. Score it exactly as written, and flag it on the results sheet so no one reads a high count as a good thing.
- Look only at the room's permanent walls, floor and ceiling. Ignore posters, student work and furniture.
- The room counts as uniform if it has one wall color, one floor material and one type of ceiling tile.
- It does not count as uniform if it has an accent wall, a second floor material marking off an area, a wood ceiling panel, or a colored ceiling element.
VI_2 Display of Student Work or Artwork
Is there a designated display surface for student work that currently shows student work?
- Look for a permanent surface set aside for displaying student work, such as a tackboard, tack strip, frame system or magnetic wall, or a defined display area just outside the room.
- Work taped to painted walls, windows, doors or cabinet fronts does not count.
- Taped-up work suggests the display surface is missing or in the wrong place, so compare with FF_3.
- Mark Yes if most sampled rooms have a designated surface and it currently shows student work.
VI_3 Visual Clutter
What best describes wall display density in this room?
- Stand at the back of the room and photograph the front teaching wall and one side wall straight on, at seated eye height.
- Score from the photo, not from memory. This is the most subjective item in the inventory.
- Estimate how much of the wall is covered, using the ceiling grid, the lines of the block wall, or a grid laid over the photo as a guide.
- Choose "Sparse" if less than about 20% of the wall is covered.
- Choose "Moderate" if about 20–50% is covered, items are organized with bare wall between them, and the teaching wall is easy to read.
- Choose "Dense" if about 50–80% is covered but items are lined up and don't overlap.
- Choose "Cluttered" if more than about 80% is covered, or at any level if items overlap, hang from the ceiling, or cover windows or doors.
- If the front wall looks different from the side walls, score it separately. Research on student attention (Fisher, Godwin & Seltman, 2014) shows the front wall matters most.